Fujitsu PRIMERGY RX300 S7 Upgrade And Maintenance Manual
Manufacturer | Fujitsu |
---|---|
Type | Upgrade and maintenance manual PDF |
Pages | 560 Pages |
Updated | Sep 3, 2021 |
Category | Server |
Table of Contents
-
Copyright and trademarks
2 -
Version history
25 -
Introduction
27 -
Where to find which information
28 -
Notational conventions
29 -
Before you start
31 -
Classification of procedures
33 -
Upgrade and Repair Units (URU)
34 -
Field Replaceable Units (FRU)
35 -
Average task duration
36 -
Tools you need at hand
37 -
Documents you need at hand
40 -
Important information
43 -
ENERGY STAR
51 -
FCC Class A Compliance Statement
52 -
Environmental protection
53 -
Basic hardware procedures
55 -
Locating the defective server
56 -
Determining the error class
57 -
Customer Self Service (CSS) indicator
59 -
Locating the defective component
60 -
Local diagnostic indicators on the system board
62 -
Opening the rack door
64 -
Shutting down the server
65 -
Disconnecting power cords
66 -
Extending/removing the server from the rack
68 -
Extending the server out of the rack
69 -
Removing the server from the rack
70 -
Opening the server
72 -
Removing the air duct
73 -
Installing the air duct
74 -
Closing the server
76 -
Mounting the server in the rack
77 -
Sliding the server into the rack
80 -
Connecting the server to the power source
81 -
Switching on the server
82 -
Concluding software tasks
84 -
Basic software procedures
85 -
Disabling SVOM boot watchdog functionality
86 -
Configuring boot watchdog settings
87 -
Removing backup and optical disk media
89 -
Note on server maintenance in a Multipath I/O environment
90 -
Switching on the ID indicator
91 -
Completing the maintenance task
92 -
Updating or recovering the iRMC
93 -
Verifying system information backup / restore
94 -
Updating RAID controller firmware
96 -
Enabling Option ROM scan
97 -
Verifying and configuring the backup software solution
98 -
Resetting the boot retry counter
99 -
Enabling SVOM boot watchdog functionality
101 -
Verifying the memory mode
102 -
Verifying the system time settings
103 -
Viewing and clearing the System Event Log (SEL)
104 -
Clearing the SEL
105 -
Enabling BitLocker functionality
107 -
Performing a RAID array rebuild
108 -
Looking up WWN addresses
109 -
Using the Chassis ID Prom Tool
111 -
After replacing / upgrading LAN controllers
112 -
Specifying the chassis model
113 -
Performing a fan test after replacing a defective fan
114 -
Power supply
117 -
Installing PSU modules
118 -
Removing a PSU dummy module
119 -
Installing a PSU module
120 -
Removing PSU modules
121 -
Removing a PSU module
122 -
Installing a PSU dummy module
123 -
Replacing PSU modules
124 -
Installing the new PSU module
125 -
Upgrading PSU from 450 W to 800 W
126 -
Removing the PSU module
127 -
Concluding steps
128 -
Replacing the power backplane
129 -
Disconnecting power cables
130 -
Removing the power backplane
131 -
Installing the power backplane
133 -
Reconnecting power cables
135 -
Hard disk drives / solid state drives
137 -
Basic procedure
138 -
Installing 3.5-inch HDD modules
140 -
Installing a 3.5-inch HDD module
141 -
Removing 3.5-inch HDD modules
142 -
Preliminary steps
143 -
Installing a 3.5-inch HDD dummy module
144 -
Replacing a 3.5-inch HDD module
145 -
Removing a 3.5-inch HDD module
146 -
Installing 2.5-inch HDD / SSD modules
151 -
Removing a 2.5-inch HDD / SSD dummy module
152 -
Installing a 2.5-inch HDD / SSD module
153 -
Removing 2.5-inch HDD / SSD modules
154 -
Removing a 2.5-inch HDD / SSD module
155 -
Installing a 2.5-inch HDD / SSD dummy module
156 -
Replacing a 2.5-inch HDD / SSD module
157 -
Required tools
158 -
Replacing SAS / SATA HDD / SSD backplanes
159 -
Removing the 3.5-inch HDD SAS / SATA backplane
160 -
Installing the 3.5-inch HDD SAS backplane
162 -
Replacing the 4x 2.5-inch HDD SAS backplane
164 -
Removing the HDD cage
166 -
Removing the 4x 2.5-inch SAS HDD backplane
167 -
Installing the 4x 2.5-inch HDD SAS backplane
168 -
Installing the HDD cage
169 -
Replacing the 12x 2.5-inch HDD SAS backplane
170 -
Removing the 12x2.5-inch HDD SAS backplane
172 -
Installing the 12x 2.5-inch HDD SAS backplane
173 -
System fan
177 -
Replacing the fan module
178 -
Removing a fan module
179 -
Installing a fan module
180 -
Removing the fan box
181 -
Removing fan module 2 and 4
182 -
Installing the fan box
184 -
Expansion cards and backup units
187 -
Expansion cards
191 -
Removing PCI slot bracket
192 -
Installing an expansion card
193 -
Connecting cables to the expansion card
194 -
Removing expansion cards
196 -
Removing an expansion card
197 -
Installing a PCI slot bracket
198 -
Replacing expansion cards
199 -
Connecting a battery backup unit to the expansion card
201 -
SAS RAID controller in PCI slot 7
203 -
Preparing the SAS RAID controller
204 -
Connecting a backup unit to the expansion card
205 -
Removing the SAS RAID controller
207 -
Replacing the SAS RAID controller
210 -
Removing the defective SAS RAID controller
211 -
Modular LAN controller in PCI slot 1
213 -
Preparing the Modular LAN controller
215 -
Installing the Modular LAN controller
217 -
Removing the Modular LAN controller
221 -
Replacing the Modular LAN controller
225 -
Battery Backup Units (BBU)
227 -
Preparing the BBU
229 -
Installing the BBU holder onto the air duct
230 -
Installing the air duct with a BBU
232 -
Removing a BBU
234 -
Removing the air duct with a BBU
235 -
Removing the BBU holder from the air duct
236 -
Replacing a BBU
237 -
Removing a BBU from the air duct
238 -
Installing a new BBU
239 -
Flash Backup Units (FBU)
241 -
Preparing the FBU
244 -
Installing the FBU holder onto the air duct
246 -
Removing an FBU
248 -
Removing the air duct with an FBU
249 -
Removing the FBU holder from the air duct
250 -
Replacing an FBU
251 -
Removing an FBU from the air duct
252 -
Installing a new FBU
253 -
Additional tasks
254 -
General instructions
255 -
Network adapter D2745
257 -
Network adapter D2755
259 -
USB 3.0 interface card D3305
261 -
Handling SFP+ transceiver modules
262 -
Removing an SFP+ transceiver module
268 -
Replacing SFP+ transceiver modules
270 -
Main memory
271 -
Memory sequence
272 -
Independant Channel mode
274 -
Mirrored Channel and Performance modes
275 -
Rank Sparing mode
276 -
Installing memory modules
280 -
Installing a memory module
281 -
Removing memory modules
284 -
Replacing memory modules
287 -
Removing a memory module
288 -
Processors
289 -
Basic information
290 -
Installing processors
291 -
Installing the processor
292 -
Removing the protective socket cover
297 -
Closing th load
299 -
Removing processors
302 -
Removing a processor
303 -
Removing the processor
307 -
Closing the load plate
308 -
Installing the protective cover
309 -
Upgrading or replacing processors
313 -
Upgrading or replacing a processor
314 -
Handling processor heat sinks
324 -
Installing processor heat sinks
325 -
Preparing the heat sink and processor
326 -
Installing the heat sink
327 -
Removing processor heat sinks
329 -
Replacing processor heat sinks
331 -
Applying thermal paste
332 -
Accessible drives
335 -
Basic informations
336 -
Installing a Local Service Display (LSD) module
337 -
Removing the LSD dummy cover
338 -
Installing a LSD module
339 -
Removing a LSD module
341 -
Removing the LSD module
342 -
Replacing a LSD module
344 -
Removing the defective LSD module
345 -
Installing the optical disk drive (ODD)
346 -
Removing the ODD dummy
347 -
Preparing an ODD
348 -
Installing an ODD
350 -
Removing the optical disc drive (ODD)
351 -
Removing the ODD
352 -
Replacing an ODD
355 -
Removing the defective ODD
356 -
Installing an RDX/DAT drive in 3.5-inch version
358 -
Installing an RDX/DAT drive in the cage
359 -
Installing the RDX/DAT drive
360 -
Connecting the RDX/DAT drive
361 -
Connecting the RDX/DAT drive to the system board
362 -
12.8.5.2 Connecting the RDX/DAT drive to the USB 3.0 interface card
363 -
Removing an RDX/DAT drive in 3.5-inch version
365 -
Removing the drive cage
366 -
Removing an RDX/DAT drive out of the cage
367 -
Replacing the RDX/DAT drive in 3.5-inch version
369 -
Removing the defective RDX/DAT drive
370 -
Installing an RDX/DAT drive in 2.5-inch version
371 -
12.11.5.2 Connecting the RDX/DAT drive to the USB 3.0 interface card
376 -
Removing an RDX/DAT drive in 2.5-inch version
378 -
Replacing the RDX/DAT drive in 2.5-inch version
383 -
Installing the new RDX/DAT drive
384 -
Installing an LTO drive in 2.5-inch version
385 -
Removing the tape dummy
388 -
Installing an LTO drive in the cage
389 -
Installing the LTO cage
392 -
Removing an LTO drive in 2.5-inch version
395 -
Removing an LTO drive out of the cage
399 -
Installing the dummy drive
401 -
Replacing the LTO drive in 2.5-inch version
404 -
Removing the defective LTO drive
405 -
Front panel
407 -
Replacing the front panel module
408 -
Removing the front panel module
410 -
Installing the front panel module
413 -
Front VGA connector
417 -
Preparing the front panel module
418 -
Installing the front VGA connector
419 -
Re-installing the front panel module
420 -
Removing the front VGA connector
421 -
Removing the front VGA cable
422 -
Replacing the front VGA connector
424 -
Installing the new front VGA connector
425 -
Front LAN connector
426 -
Installing the front LAN connector
428 -
Using the front management LAN connector
435 -
Removing the front LAN connector
436 -
Removing the front LAN board
437 -
Replacing the front LAN connector and board
443 -
Installing the new front LAN connector
444 -
Front cage
445 -
Removing the front panel cage
446 -
Re-installing the front panel cage
447 -
System board and components
451 -
Removing the battery
453 -
Installing the CMOS battery
454 -
USB Flash Module (UFM)
456 -
Installing the UFM board
457 -
Software configuration
460 -
Removing the UFM board
461 -
Replacing the UFM board
463 -
Removing the UFM
464 -
Trusted Platform Module (TPM)
468 -
Installing the TPM board
469 -
Removing the TPM board
474 -
Replacing the TPM board
479 -
Removing the TPM
480 -
Re-installing the TPM
481 -
Onboard SAS enabling key
482 -
Installing the onboard SAS enabling key
483 -
Removing the onboard SAS enabling key
484 -
Removing onboard SAS enabling key
485 -
Replacing the onboard SAS enabling key
486 -
Replacing the system board
487 -
Removing the system board
491 -
Installing the system board
493 -
Swapping processors
495 -
Conversion configurations
499 -
SAS cabling
500 -
Basic Procedures
501 -
Removing HDD cages and front panel cage
503 -
Installing HDD cage and front panel cage
504 -
Installing the front cover
505 -
Panelhousing in bay 5
506 -
Converting
507 -
Configuration 2 to configuration 7
510 -
Configuration 2 to configuration 3
514 -
Configuration 3 to configuration 6
517 -
Configuration 4 to configuration 7
520 -
Configuration 4 to configuration 8
522 -
Configuration 7 to configuration 8
523 -
Cables
525 -
Cabling
528 -
Configuration 2
530 -
Configuration 3
532 -
Configuration 4
534 -
Configuration 5
535 -
Configuration 6
537 -
Configuration 7
539 -
Configuration 8
540 -
Appendix
541 -
Server rear
543 -
Server interior
544 -
Configuration tables
545 -
Connectors and indicators
546 -
Onboard settings
548 -
Onboard indicators and controls
550 -
Connectors and indicators on the I/O panel
552 -
I/O panel indicators
553 -
Indicators on the front panel
555 -
Minimum startup configuration
558
Related Manuals
Below are links to the text of a wide variety of documents related to the Fujitsu PRIMERGY RX300 S7 Upgrade And Maintenance Manual.
- Fujitsu PRIMERGY TX300 S7 Upgrade And Maintenance Manual
- Fujitsu PRIMERGY RX100 S7 Upgrade And Maintenance Manual
- Fujitsu PRIMERGY TX300 S7 Upgrade And Maintenance Manual
- Fujitsu PRIMERGY TX300 S7 Upgrade And Maintenance Manual
- Fujitsu PRIMERGY RX300 S8 Upgrade And Maintenance Manual
- Fujitsu PRIMERGY TX300 S8 Upgrade And Maintenance Manual
Recommended for You
White Rodgers 1F95-1277 Installation And Operating Instructions Manual
Orion vortex R10 Instruction Manual
Impex Marcy Platinum MP-4500 Owner's Manual
GE Profile JVM1790 Owner's Manual
JVC KD-X320BT Instruction Manual
Paslode IM250 II Operating Manual
True TSSU-48-12 Specification Sheet