Fujitsu PRIMERGY RX300 S7 Upgrade And Maintenance Manual

Manufacturer
Type
Pages 560 Pages
Updated Sep 3, 2021
Category Server

Table of Contents

  • Copyright and trademarks

    2
  • Version history

    25
  • Introduction

    27
  • Where to find which information

    28
  • Notational conventions

    29
  • Before you start

    31
  • Classification of procedures

    33
  • Upgrade and Repair Units (URU)

    34
  • Field Replaceable Units (FRU)

    35
  • Average task duration

    36
  • Tools you need at hand

    37
  • Documents you need at hand

    40
  • Important information

    43
  • ENERGY STAR

    51
  • FCC Class A Compliance Statement

    52
  • Environmental protection

    53
  • Basic hardware procedures

    55
  • Locating the defective server

    56
  • Determining the error class

    57
  • Customer Self Service (CSS) indicator

    59
  • Locating the defective component

    60
  • Local diagnostic indicators on the system board

    62
  • Opening the rack door

    64
  • Shutting down the server

    65
  • Disconnecting power cords

    66
  • Extending/removing the server from the rack

    68
  • Extending the server out of the rack

    69
  • Removing the server from the rack

    70
  • Opening the server

    72
  • Removing the air duct

    73
  • Installing the air duct

    74
  • Closing the server

    76
  • Mounting the server in the rack

    77
  • Sliding the server into the rack

    80
  • Connecting the server to the power source

    81
  • Switching on the server

    82
  • Concluding software tasks

    84
  • Basic software procedures

    85
  • Disabling SVOM boot watchdog functionality

    86
  • Configuring boot watchdog settings

    87
  • Removing backup and optical disk media

    89
  • Note on server maintenance in a Multipath I/O environment

    90
  • Switching on the ID indicator

    91
  • Completing the maintenance task

    92
  • Updating or recovering the iRMC

    93
  • Verifying system information backup / restore

    94
  • Updating RAID controller firmware

    96
  • Enabling Option ROM scan

    97
  • Verifying and configuring the backup software solution

    98
  • Resetting the boot retry counter

    99
  • Enabling SVOM boot watchdog functionality

    101
  • Verifying the memory mode

    102
  • Verifying the system time settings

    103
  • Viewing and clearing the System Event Log (SEL)

    104
  • Clearing the SEL

    105
  • Enabling BitLocker functionality

    107
  • Performing a RAID array rebuild

    108
  • Looking up WWN addresses

    109
  • Using the Chassis ID Prom Tool

    111
  • After replacing / upgrading LAN controllers

    112
  • Specifying the chassis model

    113
  • Performing a fan test after replacing a defective fan

    114
  • Power supply

    117
  • Installing PSU modules

    118
  • Removing a PSU dummy module

    119
  • Installing a PSU module

    120
  • Removing PSU modules

    121
  • Removing a PSU module

    122
  • Installing a PSU dummy module

    123
  • Replacing PSU modules

    124
  • Installing the new PSU module

    125
  • Upgrading PSU from 450 W to 800 W

    126
  • Removing the PSU module

    127
  • Concluding steps

    128
  • Replacing the power backplane

    129
  • Disconnecting power cables

    130
  • Removing the power backplane

    131
  • Installing the power backplane

    133
  • Reconnecting power cables

    135
  • Hard disk drives / solid state drives

    137
  • Basic procedure

    138
  • Installing 3.5-inch HDD modules

    140
  • Installing a 3.5-inch HDD module

    141
  • Removing 3.5-inch HDD modules

    142
  • Preliminary steps

    143
  • Installing a 3.5-inch HDD dummy module

    144
  • Replacing a 3.5-inch HDD module

    145
  • Removing a 3.5-inch HDD module

    146
  • Installing 2.5-inch HDD / SSD modules

    151
  • Removing a 2.5-inch HDD / SSD dummy module

    152
  • Installing a 2.5-inch HDD / SSD module

    153
  • Removing 2.5-inch HDD / SSD modules

    154
  • Removing a 2.5-inch HDD / SSD module

    155
  • Installing a 2.5-inch HDD / SSD dummy module

    156
  • Replacing a 2.5-inch HDD / SSD module

    157
  • Required tools

    158
  • Replacing SAS / SATA HDD / SSD backplanes

    159
  • Removing the 3.5-inch HDD SAS / SATA backplane

    160
  • Installing the 3.5-inch HDD SAS backplane

    162
  • Replacing the 4x 2.5-inch HDD SAS backplane

    164
  • Removing the HDD cage

    166
  • Removing the 4x 2.5-inch SAS HDD backplane

    167
  • Installing the 4x 2.5-inch HDD SAS backplane

    168
  • Installing the HDD cage

    169
  • Replacing the 12x 2.5-inch HDD SAS backplane

    170
  • Removing the 12x2.5-inch HDD SAS backplane

    172
  • Installing the 12x 2.5-inch HDD SAS backplane

    173
  • System fan

    177
  • Replacing the fan module

    178
  • Removing a fan module

    179
  • Installing a fan module

    180
  • Removing the fan box

    181
  • Removing fan module 2 and 4

    182
  • Installing the fan box

    184
  • Expansion cards and backup units

    187
  • Expansion cards

    191
  • Removing PCI slot bracket

    192
  • Installing an expansion card

    193
  • Connecting cables to the expansion card

    194
  • Removing expansion cards

    196
  • Removing an expansion card

    197
  • Installing a PCI slot bracket

    198
  • Replacing expansion cards

    199
  • Connecting a battery backup unit to the expansion card

    201
  • SAS RAID controller in PCI slot 7

    203
  • Preparing the SAS RAID controller

    204
  • Connecting a backup unit to the expansion card

    205
  • Removing the SAS RAID controller

    207
  • Replacing the SAS RAID controller

    210
  • Removing the defective SAS RAID controller

    211
  • Modular LAN controller in PCI slot 1

    213
  • Preparing the Modular LAN controller

    215
  • Installing the Modular LAN controller

    217
  • Removing the Modular LAN controller

    221
  • Replacing the Modular LAN controller

    225
  • Battery Backup Units (BBU)

    227
  • Preparing the BBU

    229
  • Installing the BBU holder onto the air duct

    230
  • Installing the air duct with a BBU

    232
  • Removing a BBU

    234
  • Removing the air duct with a BBU

    235
  • Removing the BBU holder from the air duct

    236
  • Replacing a BBU

    237
  • Removing a BBU from the air duct

    238
  • Installing a new BBU

    239
  • Flash Backup Units (FBU)

    241
  • Preparing the FBU

    244
  • Installing the FBU holder onto the air duct

    246
  • Removing an FBU

    248
  • Removing the air duct with an FBU

    249
  • Removing the FBU holder from the air duct

    250
  • Replacing an FBU

    251
  • Removing an FBU from the air duct

    252
  • Installing a new FBU

    253
  • Additional tasks

    254
  • General instructions

    255
  • Network adapter D2745

    257
  • Network adapter D2755

    259
  • USB 3.0 interface card D3305

    261
  • Handling SFP+ transceiver modules

    262
  • Removing an SFP+ transceiver module

    268
  • Replacing SFP+ transceiver modules

    270
  • Main memory

    271
  • Memory sequence

    272
  • Independant Channel mode

    274
  • Mirrored Channel and Performance modes

    275
  • Rank Sparing mode

    276
  • Installing memory modules

    280
  • Installing a memory module

    281
  • Removing memory modules

    284
  • Replacing memory modules

    287
  • Removing a memory module

    288
  • Processors

    289
  • Basic information

    290
  • Installing processors

    291
  • Installing the processor

    292
  • Removing the protective socket cover

    297
  • Closing th load

    299
  • Removing processors

    302
  • Removing a processor

    303
  • Removing the processor

    307
  • Closing the load plate

    308
  • Installing the protective cover

    309
  • Upgrading or replacing processors

    313
  • Upgrading or replacing a processor

    314
  • Handling processor heat sinks

    324
  • Installing processor heat sinks

    325
  • Preparing the heat sink and processor

    326
  • Installing the heat sink

    327
  • Removing processor heat sinks

    329
  • Replacing processor heat sinks

    331
  • Applying thermal paste

    332
  • Accessible drives

    335
  • Basic informations

    336
  • Installing a Local Service Display (LSD) module

    337
  • Removing the LSD dummy cover

    338
  • Installing a LSD module

    339
  • Removing a LSD module

    341
  • Removing the LSD module

    342
  • Replacing a LSD module

    344
  • Removing the defective LSD module

    345
  • Installing the optical disk drive (ODD)

    346
  • Removing the ODD dummy

    347
  • Preparing an ODD

    348
  • Installing an ODD

    350
  • Removing the optical disc drive (ODD)

    351
  • Removing the ODD

    352
  • Replacing an ODD

    355
  • Removing the defective ODD

    356
  • Installing an RDX/DAT drive in 3.5-inch version

    358
  • Installing an RDX/DAT drive in the cage

    359
  • Installing the RDX/DAT drive

    360
  • Connecting the RDX/DAT drive

    361
  • Connecting the RDX/DAT drive to the system board

    362
  • 12.8.5.2 Connecting the RDX/DAT drive to the USB 3.0 interface card

    363
  • Removing an RDX/DAT drive in 3.5-inch version

    365
  • Removing the drive cage

    366
  • Removing an RDX/DAT drive out of the cage

    367
  • Replacing the RDX/DAT drive in 3.5-inch version

    369
  • Removing the defective RDX/DAT drive

    370
  • Installing an RDX/DAT drive in 2.5-inch version

    371
  • 12.11.5.2 Connecting the RDX/DAT drive to the USB 3.0 interface card

    376
  • Removing an RDX/DAT drive in 2.5-inch version

    378
  • Replacing the RDX/DAT drive in 2.5-inch version

    383
  • Installing the new RDX/DAT drive

    384
  • Installing an LTO drive in 2.5-inch version

    385
  • Removing the tape dummy

    388
  • Installing an LTO drive in the cage

    389
  • Installing the LTO cage

    392
  • Removing an LTO drive in 2.5-inch version

    395
  • Removing an LTO drive out of the cage

    399
  • Installing the dummy drive

    401
  • Replacing the LTO drive in 2.5-inch version

    404
  • Removing the defective LTO drive

    405
  • Front panel

    407
  • Replacing the front panel module

    408
  • Removing the front panel module

    410
  • Installing the front panel module

    413
  • Front VGA connector

    417
  • Preparing the front panel module

    418
  • Installing the front VGA connector

    419
  • Re-installing the front panel module

    420
  • Removing the front VGA connector

    421
  • Removing the front VGA cable

    422
  • Replacing the front VGA connector

    424
  • Installing the new front VGA connector

    425
  • Front LAN connector

    426
  • Installing the front LAN connector

    428
  • Using the front management LAN connector

    435
  • Removing the front LAN connector

    436
  • Removing the front LAN board

    437
  • Replacing the front LAN connector and board

    443
  • Installing the new front LAN connector

    444
  • Front cage

    445
  • Removing the front panel cage

    446
  • Re-installing the front panel cage

    447
  • System board and components

    451
  • Removing the battery

    453
  • Installing the CMOS battery

    454
  • USB Flash Module (UFM)

    456
  • Installing the UFM board

    457
  • Software configuration

    460
  • Removing the UFM board

    461
  • Replacing the UFM board

    463
  • Removing the UFM

    464
  • Trusted Platform Module (TPM)

    468
  • Installing the TPM board

    469
  • Removing the TPM board

    474
  • Replacing the TPM board

    479
  • Removing the TPM

    480
  • Re-installing the TPM

    481
  • Onboard SAS enabling key

    482
  • Installing the onboard SAS enabling key

    483
  • Removing the onboard SAS enabling key

    484
  • Removing onboard SAS enabling key

    485
  • Replacing the onboard SAS enabling key

    486
  • Replacing the system board

    487
  • Removing the system board

    491
  • Installing the system board

    493
  • Swapping processors

    495
  • Conversion configurations

    499
  • SAS cabling

    500
  • Basic Procedures

    501
  • Removing HDD cages and front panel cage

    503
  • Installing HDD cage and front panel cage

    504
  • Installing the front cover

    505
  • Panelhousing in bay 5

    506
  • Converting

    507
  • Configuration 2 to configuration 7

    510
  • Configuration 2 to configuration 3

    514
  • Configuration 3 to configuration 6

    517
  • Configuration 4 to configuration 7

    520
  • Configuration 4 to configuration 8

    522
  • Configuration 7 to configuration 8

    523
  • Cables

    525
  • Cabling

    528
  • Configuration 2

    530
  • Configuration 3

    532
  • Configuration 4

    534
  • Configuration 5

    535
  • Configuration 6

    537
  • Configuration 7

    539
  • Configuration 8

    540
  • Appendix

    541
  • Server rear

    543
  • Server interior

    544
  • Configuration tables

    545
  • Connectors and indicators

    546
  • Onboard settings

    548
  • Onboard indicators and controls

    550
  • Connectors and indicators on the I/O panel

    552
  • I/O panel indicators

    553
  • Indicators on the front panel

    555
  • Minimum startup configuration

    558

Related Manuals

Below are links to the text of a wide variety of documents related to the Fujitsu PRIMERGY RX300 S7 Upgrade And Maintenance Manual.